Free Next Day Delivery

Direct from the Brand

Aftersales Support

Support

Vacmaster AM201R 550 CFM Portable Air Mover

AM201R

Learn how to set up and use your air mover with instruction manuals, user guides, and FAQs.

Download Instruction Manual
Setting Up

1) Placement and Clearance
Place the air mover on a flat, stable surface. Ensure there is at least a foot of clearance on each side and keep the intake grills away from loose fabrics or debris.

2)Select Operational Angle
Direct the air mover at your target area by selecting one of the three standing positions (horizontal, 45-degree, or 90-degree).

3)Power Connection
Verify the on/off switch is set to "0" (OFF), then plug the power cord into a suitable grounded power outlet.

4)Manual Speed Control
Switch the power to "I" (ON). Turn the speed control knob to I (Low), II (Medium), or III (Maximum). The indicator light will glow Green to show it is running.

5)Remote Control Activation
To use the remote, turn the control knob to the Wi-Fi symbol. The indicator light will turn Red (Standby). Press the Power button on the remote to start the unit at the lowest speed.

6)Remote Speed Adjustment
While in remote mode, press the I, II, or III buttons on the remote to change speeds. Press the Power button again to return the unit to Standby.

7)Pairing a Replacement Remote
Switch the unit to the Wi-Fi position and turn the power ON. Within the first 5 seconds, immediately press and hold the Power button on the remote until the red light stops flashing.

8)Remote Storage
Secure the remote into the included strap holder. You can attach this strap to the handle of the unit or nearby equipment for easy access.

9)Power Down and Storage
After use, switch the power to "0" (OFF), unplug the cord, and store the unit in a dry place. Do not stack units vertically during operation.

Maintenance

1)Regular Inspection
Inspect the plug and the power cord before and after each use to ensure they have not been damaged. If any damage is found, stop using the air mover immediately and replace the damaged parts.

2)Grill Cleaning
Keep the air intake and air discharge grills free of any dirt or debris. Ensure the intake grills, discharge grill, and impeller are always in place during operation to maintain safety and airflow.

3)Proper Cord Storage
Before storing the unit, ensure the on/off switch is turned to the "0" OFF position and unplug it from the outlet. Wrap the power cord securely around the base of the handle to prevent tripping or damage.

4)Stacking for Storage
To conserve space, you can stack up to three units together. Insert the pegs on the intake grill into the peg receiver on the opposite side of the partner unit. Only stack on a stable, level surface and do not turn on the unit while it is stacked.

5)Remote Battery Replacement
When the remote response weakens, remove the 3 screws on the rear casing to access the battery. Replace it with a new 27A 12V battery cell, ensuring the positive and negative connections are correctly positioned.

6)Testing the Remote
After replacing the battery, press any button to test. The indicator light on the remote should illuminate RED, confirming the battery is installed correctly and the remote is functional.

7)Storage Environment

Store the air mover in a dry, indoor environment. Keep it away from hazardous materials, such as toxic, flammable, or explosive substances. Do not store the equipment outdoors.

Specifications

Model Number

AM201R

Power Supply

120V

Power Cord Length

12 ft

Adjustable Positions

0°, 45° & 90°

Max Air Flow Speed

51 km/h (32 mph)

Remote Control

Yes

Airflow

550 CFM

Speeds

3 Speeds

Motor Power

124W

Motor Voltage

120V

Recommended Uses For Product

Cooling

Noise Level

61 Decibels

Dimensions

12.99"D x 12.6"W x 10.43"H

Amperage

1.3 Amps

Controller Type

Remote Control

Weight

3.63kg

Special Features

Portable

Warranty

2 Year

Spare Parts

Our aim is to keep it personal. Our friendly customer service team are there if you need a helping hand.

Contact Us

Support

Frequently Asked Questions

Why is the air mover not working?

This can be caused by:

1)No power supply. Check the power supply, cord, breakers, and fuses.

2)Faulty power cord. Unplug and check the power cord. If damaged, have it repaired by qualified personnel or contact the after-sales helpline.

3)On/Off switch in the wrong position. Move the switch to the "I" ON position.

4)The On/Off switch is faulty. Have the switch replaced by qualified personnel or contact the after-sales helpline.

Why does the air mover make a loud scraping noise while working?

A loud scraping noise may indicate damage causing a deformed housing or misaligned blower wheel. The recommended solution is to replace the air mover.

Why does the air mover run but the centrifugal fan does not rotate?

This can be caused by:

1)The centrifugal fan and housing are jammed. The solution is to replace the air mover.

2)There is a problem with the switch or capacitor. The solution is to replace the air mover.

Why is the air mover vibrating excessively while working?

This can be caused by:

1)The centrifugal fan has dirt build-up. Have the air mover inspected by qualified personnel or contact the after-sales helpline.

2)The centrifugal fan is damaged or the motor is bent. The solution is to replace the air mover.

Why is the remote control not working?

This can be caused by:

1)The remote control is not paired with the air mover. Reset the remote control following the instructions in the manual.

2)The battery is dead. Replace the battery or the remote control.

3)The remote control is damaged. Replace with a new remote control.

Why does the status light on the remote control no longer illuminate when pressed?

This can be caused by:

1)The battery is dead. Replace the battery or the remote control.